Engineering Workbenchv0.6.0
Calculates in your browser

TOOL 01 / RF FOUNDATIONS

RF Power & Units

From watts to decibels. Every reference, every equation, in view.

Equations & assumptions

Power converter

Decimal or scientific notation, e.g. 1e-6. Changing the unit reinterprets the entered value.

Try
dBm ref. 1 mW—
dBW ref. 1 W—
W—
mW—
µW—
nW—

Results update as you type.

VOLTAGE ACROSS THE LOAD
—V RMS
VRMS = √(P · R)

Average power dissipated in a pure resistance. This is the loaded RMS voltage.

Power ratio

Convert a change in power between dB and a linear multiplier, P₂ / P₁.

Positive dB = increase; negative dB = decrease. P₁ must be greater than zero.

Try
LINEAR POWER MULTIPLIER
—×

— dB

3 dB is close to doubling. Exactly ×2 is 3.0103… dB.

Power ratior = 10ΔdB / 10ΔdB = 10 log₁₀(r)

Precision applies throughout: linear values use significant figures; dB uses 3 decimal places. Display rounding does not change the calculation.

AT A GLANCE

Quick references

Rounded to the selected display precision

Absolute power

50 Ω load
Power conversions and RMS voltage at the selected load
dBmdBWPowerV RMS

The voltage column follows your load setting above.

Power change

P₂ / P₁
Decibel changes and their linear power ratios
Change (dB)Power multiplier

±3 dB and ±6 dB are approximate doubling / quadrupling rules.

Equations & assumptions

Absolute power

1 W = 10³ mW = 10⁶ µW = 10⁹ nW

LdBW = 10 log₁₀(P / 1 W)

LdBm = 10 log₁₀(P / 1 mW) = LdBW + 30

P [W] = 10LdBW / 10 = 10(LdBm − 30) / 10

dBm and dBW are absolute levels with different references. dB alone expresses a ratio. Zero linear power has no finite logarithm; it is shown as −∞ dBm / dBW.

Resistive load & ratios

P = VRMS² / R   →   VRMS = √(P · R)

ΔdB = 10 log₁₀(P₂ / P₁)

Power is the average real power delivered to the stated, purely resistive load. No source impedance, mismatch, cable loss or reactive impedance is modelled. RMS does not require a sine wave under this assumption; peak and peak-to-peak voltage depend on waveform and are not calculated.

The 20 log₁₀ voltage-ratio rule corresponds to power ratios only when both resistances are equal. Here all ratio calculations use powers and the factor 10.

Supported ranges, rounding & verification

Power: zero, or 1e-30 to 1e30 W; equivalently −300 to +300 dBW / −270 to +330 dBm. Enter zero in a linear unit. All numeric inputs must be finite.

Load: 1e-6 to 1e9 Ω. Ratio: zero, or 1e-30 to 1e30 (−300 to +300 dB). A zero ratio means P₂ = 0 with P₁ > 0 and is shown as −∞ dB; 0 / 0 is undefined.

Input: dot decimals and scientific notation; no separators or unit suffixes. A Unicode minus sign is accepted. These numerical limits keep all supported calculations comfortably within floating-point range; they are not component ratings.

Display: choose 3, 6 or 9 significant figures for linear results; dB values use 1, 3 or 6 decimal places respectively. Scientific notation is used below 0.001 or from 1,000,000. Zero displays as 0. Trailing zeroes indicate display precision, not measurement accuracy.

Calculation: JavaScript double precision, with rounding only for display. Calculation checks cover published anchors, invalid inputs, zero, boundary values and reference tables, with separate high-precision numerical comparisons. Numerical checks do not establish measurement accuracy or suitability for a particular installation.

Equation references: ITU-T B.12, Annex A (historical; withdrawn) · Analog Devices, Measurement and Control of RF Power (Part I). These external references need internet access; calculations run in your browser after the page loads.